Differential Pairs

Overview

This is the third tab of the Design Rule Manager, opened by the Design Rule Manager command on the Technology menu. It allows you to create and configure named differential pairs.

Differential pair routing is available from PCB Level 2 onwards.

DP Class

The DP Class selector with the New, Rename and Delete buttons alongside it

The DP Class selector with the New, Rename and Delete buttons alongside it

The DP Class combo at the top of the tab chooses the differential pair you then configure in the rest of the dialogue form.

Three buttons sit alongside it and are always available. New creates a pair, opening the Create New Differential Pair dialogue in which you name it; Rename opens the Rename Differential Pair dialogue for the selected pair; Delete removes it. A differential pair can also be created from the place wire label command on the schematic, which is often the more convenient route when you are labelling the signals anyway.

The linked topic below provides more detailed explanation on how to set up and route differential pairs in Proteus.

Differential Pairs

Net Class

Here you can select a net class to associate with the differential pair. If you haven't already done so you should switch back to the Net Classes tab and create one before assigning it here. Creating a net class for the differential pairs is important as it will allow you to:

  1. Specify trace width for routing.
  2. Scope design rules and set clearances to other objects.

Unlike normal net classes you do not need to place a wire label on the schematic to assign the net class. Instead, you assign the net class to the differential pair in this dialogue form. The differential pair itself has a label on the schematic so Proteus already knows which signals to apply the net class to.

See Also:

Differential Pairs: Net Classes

Clearances

This section allows you to specify additional clearances specific to the differential pair itself. Standard clearances, to other objects for example, are determined by design rules in the normal way.

Min Paired Separation

This is the distance between the two tracks used in diff pair routing mode. Any increase from this distance would be considered to be unpaired and can happen either due to cornering, phase match serpentine segments or at the start and end of the routes while making connections to the pads.

Max Unpaired Separation

This is the maximum distance between the two tracks that you consider legal at any time. While the specified value will be enforced for corrective serpentine segments (during automatic phase matching) note that the actual reported maximum in the differential pair report may well be due to an unavoidable fanout or termination routing which you have placed manually.

Violations of the max unpaired length and max unpaired separation will be logged by the Pre-production checker as part of its differential pair compliance check.

We strongly recommend that you generate a differential pair report from the Project Notes module. This provides more information and clarity about whether your differential pair or pairs are compliant with your specified values.

Tolerances

This section allows you to specify tolerances for length matching and phase matching of the differential pair.

Max Phase Shift

Differential pair lengths are matched against each other. However, to ensure that the differential signal is as close to opposite as possible the track lengths need to be matched after each corner or unpaired section.

Max Phase Shift is therefore defined as the allowable difference in track length due to a diversion or corner before serpentine routing is applied to one track to equalise their lengths.

Note that the start and end of corners depend on the direction that you route the track. Since corrective action is taken at the end of a corner the result will be different depending on where you start and finish the route.

You should therefore always check that the differential pair direction is correct after routing. This is noted in the differential pairs report or can normally be worked out from the position of the corrective serpentines. If need be you can change the direction (and therefore the phase matching) via the Reverse route direction command on the track context menu.

See Also:

Phase Matching

Correct phase shift at end

This checkbox sits alongside Max Phase Shift and decides where the corrective serpentines are placed. With it clear, Proteus corrects the phase at the end of each corner, so a route with several corners ends up with several small serpentines spread along it. Tick it and the correction is instead gathered into a single serpentine at the end of the route.

See Also:

Differential Pair Setup

Length Match Tolerance

If you match the diff pair against a target length this is the allowable difference between the length of the differential pair and the specified target length.

If you match the diff pair against another diff pair then this is the allowable difference in length between the two after matching is complete. The form carries the qualifier "(between this diff. pair. and other traces)" beside the field as a reminder that the tolerance is measured against other traces rather than within the pair itself.

See Also:

Length Matching vs Phase Matching

Max Unpaired Length

This is the maximum distance that you consider legal for any deviation from the paired separation. It is not specifically enforced by the system but it is reported along with the actual maximum in the differential pair report.

Unpaired length generally results from serpentine segments used to equalise the track lengths. To correct an overly large unpaired length you need therefore to look at the corners during routing (causing the length mismatches) and at the max unpaired separation specification (influencing the distance that the tracks are unpaired for). It can also result from fanout from the source or receiver pins, covering the etched track distance used to get from the two pins into a paired state. Generally this is routed manually by the user and is unavoidable.

The longer of the two distances is used and reported.